Specifications
General
| Conveyor Speed |
: |
Approx. 0.2 M/Sec |
| Resolution |
: |
40 SWG wire |
| Penetration |
: |
5mm of Steel |
| Power |
: |
198VACc-242 VAC, 50 Hz, 2.5Amp Max |
X-Ray Generator
| Anode Voltage |
: |
80 kV
operating. |
| Tube Current |
: |
0.55 mA
typical |
| Beam divergence |
: |
80 degree |
| Cooling |
: |
Sealed oil bath |
Image Processing
| Sensor |
: |
Folder array, 448 diodes |
| Computer |
: |
Pentium IV |
| Ram |
: |
512 |
| Digital memory |
: |
64 MB |
| Grey levels |
: |
4096 |
| Zoom |
: |
9 Sector 2.3...upto
8x linear magnification |
| Display |
: |
15" high resolution
SVGA, Flicker
free color monitor |
Health and Safety
Radiation Safety :
Complies with all applicable international radiation , health and
safety regulations including USA FDA for cabinet X-ray systems
(Federal Standard 2.1 - CFR 1020.40) and the Health and Safety
Work Act 1974 - Section 6, amended by The Customer Protection Act
1987 . Maximum leakage radiation is less than 0.1 mR/hr (1uSv/hr) in contact
with outer panels.
Film Safety: For ISO 1600/33
DIN , Guaranteed up to 10 times exposure to radiation
Standard Features
- Image Archiving
- Black
& Whit Imaging
- Pseudo Color
Imaging
- Variable Edge
Enhancement
- Variable
Contrast
- Inverse Video
- 2 to 8 times
Zoom
- High Penetration
- Low Penetration
- Variable Density
Zoom
Options
- Operator Training Programme
- Threat Image Projection (TIP)
- Voltage Stabilizer
- UPS (uninterrupted power
supply)
- Isolation Transformer
|