ECR-530
This
multi-energy system
is designed specially for screening of registered baggage / small
cargo at airports and other security hold areas. The low bed
height facilitates easy loading of heavy baggage.
|
 |

|
 |
|
Specifications
General
| Resolution |
: |
40
SWG (36 AWG) Guaranteed
42 SWG (38 AWG) Typical |
| Penetration |
: |
Steel
- 27 mm. Guaranteed
29 mm. Typical
|
| Power |
: |
185
- 250 VAC, 50Hz., single phase
5 Amp. Max. |
| Conveyor
Load Capacity |
: |
175
kg. distributed |
| Conveyor
Speed |
: |
Approx.
0.2 m/sec |
X-Ray
Generator
| Cooling |
: |
Sealed oil
bath
|
| Anode
Voltage |
: |
160 KV
rated, 140 KV
operating |
| Tube Current |
: |
1 mA rated, 0.7 mA
operating |
| Beam
Divergence |
: |
60 degree
|
Computer
Configuration
| Processor |
: |
Pentium IV Processor 2.8 GHZ minimum |
| Hard Disk |
: |
80 GB
minimum
|
| Floppy Drive |
: |
1.44 MB (3.5
in) |
| CD-ROM Drive R/W |
: |
52X Minimum |
| DDR RAM |
: |
512 MB
minimum |
| Video Memory |
: |
16 MB
minimum or better |
Image
Processing
| Sensor |
: |
Folded Array |
| Grey Levels |
: |
4096 Stored |
| Display |
: |
High
resolution SVGA 17" color monitor with
minimum 1024
x 768 pixels |
Standard
Features
-
Crystal
Clearä
-
EPX
-
Multi
Energy Imaging with four color palette for material
discrimination
-
Organic
/ Inorganic Stripping
-
High,
Low penetration
-
Variable
color stripping with save function
-
Variable
gamma with save function
-
Variable
density zoom
-
Variable
edge enhancement with save function
-
Variable
zoom X8
-
Inverse
Video
-
Black
& White Image
-
Pseudo
Color
-
Bi-directional
scanning
-
Manual
Image Archiving
-
Image
recall
-
Density
threat alert
-
Date
& Time display
-
Baggage
Counter
-
Search
Indicator
-
Full
diagnostic built-in test facility
-
Rodent
protected
-
Input
/ Output frames with SS Rollers / Drop Chute
-
Lockable
console cabinet
-
Voltage
Stabilizer with Isolation Transformer
Optional
Features
-
Target
Software
-
Threat
Image Projection (TIP)
-
Operator
Training Program
-
TIP
Network
-
Remote
Image Testing (RIT)
-
Automatic
Image Archiving
-
Operational
Hour Counter
-
UPS
Health
& Safety
-
Approved
by A.E.R.B.
-
Maximum
leakage radiation less than 0.1 mR/hr. (1 m
SV/hr) at a distance of 5 cm. from external
housing
-
Complies
with all applicable international Health & Radiation
Safety regulations including USA FDA for cabinet X-Ray Systems
-
Film
safety for ISO 1600/33 DIN, guaranteed up to 10 times
exposure to radiation
(With continuous
development of our products ECIL-Rapiscan Limited,
reserves the right to amend specification without prior
notice)
|
|